Many months ago I wrote a blog about how houses can often have moisture problems when old furnaces are replaced with high efficiency furnaces. The fix that I mentioned at the end of the blog was to install a Heat Recovery Ventilator, or HRV.  The character in that blog finally got around to installing an HRV in his house, and solved all his moisture problems! For the first time since he installed his high efficiency furnace, he no longer has condensation on his windows during the winter, and he couldn't be happier about it.

Today I'll share some basic information about how HRVs operate and why they're needed in today's newer, tighter houses.

New Houses Don't Breathe As most people know, new houses are constructed much tighter than they used to be - they don't leak air all over the place.  I've heard a lot of old-school home inspectors and building contractors complain about this, and you probably have too.  The rant goes something like this: "We build houses so damn tight that they don't breathe, and they end up rotting from the inside out!  Things were a lot better when we didn't have all these stupid house wraps."

These cranky doom sayers are only partially right - yes, we build houses tighter today, but we've also figured out how to prevent mold and moisture problems, and how to improve indoor air quality.  This is where HRVs come in.

HRVs Provide Fresh Air An HRV works by constantly bringing fresh air in to a house and exhausting stale air.    The air that gets brought in to the house gets passed through a screen at the exterior, then through a filter inside the unit, then through the HRV core, which is actually a heat exchanger.  The heat exchanger allows the fresh outdoor air to get warmed by stale indoor air right before the indoor air gets exhausted to the exterior.  This allows about 60 - 80% of the heat in the air to be re-captured.  The diagram below illustrates this principal.

HRV Heat Exchanger

To understand how an HRV works, interlock your fingers together and picture warm air flowing through fingers in one hand, and cold air flowing through the fingers in the other hand.

Interlocked Fingers2


HRVs Remove Moisture 
Besides providing fresh air, HRVs also remove a lot of moisture from the air.  Old, drafty houses get dry in the winter because they're leaky, and the moist indoor air is always getting replaced with dry outdoor air.  Not so with newer houses - they stay humid during the winter, and HRVs are often needed just to get rid of all the excess humidity.  As the warm, moist air passes by the cold air, the moisture will condense.  This is why HRVs have a drain running out the bottom.

HRV Basics SuperVentor HRV

HRVs Lower Radon Levels Because HRVs constantly change out the air in a house, an HRV will reduce radon levels when working properly.  During a recent Eden Prairie home inspection that I also performed a radon test at, I had the HRV running during the majority of the radon test, but I tripped the GFCI outlet for the last hour of the radon test during my inspection.  Look at the jump in radon levels at the house from NOT having the HRV running!  Any time a radon test is performed, if there is an HRV present at the house, it should be up and running throughout the duration of the radon test.

Radon Graph

HRVs Have Many Names If you hear any of these terms, someone is probably talking about an HRV:

  • Air-to-air heat exchanger
  • Air exchanger
  • Whole house ventilator
  • Big square thingy in the furnace room
  • VanEE system (brand name)
  • ERV

The last one, ERV, stands for Energy Recovery Ventilator.  These are similar to HRVs, but ERVs are pretty rare here in Minnesota - I think I've seen two of them, ever.  They're designed for more humid, southern climates.

If you don't have an HRV at your house and you think you need one, you could always just turn on an exhaust fan and leave it running.  This will be very inefficient, but it will change out the air in your house.  I call this the Poor Man's HRV.

Next week I'll talk about the maintenance needs of HRVs, and the week after that I'll discuss installation defects.

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

I've heard some pretty outrageous claims from window replacement companies.  The most common 'hook' for selling replacement windows is that you'll get a Return OInvestment  (ROI) because of all the money you'll save on your heating bills.  In the real world, the idea that you could ever come close to breaking even on your investment for new windows is impossible at best, and borders on downright dishonesty.  Unfortunately, a lot of consumers believe the window company's claims - I hear this myth repeated many times while doing home inspections throughout Minnesota.

To prove this, I decided to figure out how much money I would need to save every year if I just wanted to break even on the investment of new windows at my house, assuming the windows could last thirty years... although the average life expectancy for replacement windows is actually twenty years.   I've already replaced nine of the twenty-two windows in my house with newer energy-efficient windows.  If I replaced the remaining thirteen windows with incredibly energy efficient windows and I only paid $500 each, I would have to save 46% on my heating bills every year for the next 30 years just to break even!

I arrived at this number by pouring over my gas bills for the last six years, and figured out how much gas I use to heat my house on average every year.

 

  • I use an average of 520 therms per year to heat my house.
  • The average cost of gas is $0.90 / therm, which makes the average cost to heat my house every year $468.

Reuben's Gas Bill

A few details about my house:

  • Built in 1939, 1500 finished sf, 1 1/2 story.
  • 2x4 construction, most walls have about 2" of rock wool insulation.  This means the walls are very poorly insulated, so a lot of my heat loss is happening through the walls.
  • Basement is completely unfinished and uninsulated.
  • Attic / 2nd floor is insulated with about 3" of closed-cell spray foam.
  • Thirteen original single pane windows with removable storm windows installed during the winter.
  • Nine newer Low-E windows (the kind that are supposed to save energy)
  • I keep my house at 72 degrees during the winter, and I use a setback thermostat.

Assuming each new window costs $500, replacing thirteen windows would cost $6500.  To save $6500 over a period of 30 years, I would need to save $216 per year on my heating costs, or 46% or my average annual cost, which is $468.  In reality, I might end up saving somewhere around 5%.  I've already replaced almost half the windows on my house, and I haven't noticed any significant savings on my heating bills.

I'm not writing this to discourage anyone from replacing their windows -  I love new windows, and I dislike my old windows with a passion.  They're a huge pane to maintain, and I'm slowly replacing them... but every time I replace a window, I do it because I like having new windows, not because I think I'm going to save any real money on my heating bill.  A $1500 tax credit still wouldn't even get me close.

ps - when it comes time to sell your home, a house with new windows will sell for more money than a house with old windows.  Home sellers in the Minneapolis area can expect to recoup about 70% of the cost of new windows.


Reuben Saltzman, Structure Tech Home Inspections – Email – Minnesota Home Inspections


 

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

 

Registered Vacant BuildingIf you're in the market to buy a fixer-upper home in Saint Paul, there's no need to be afraid of registered vacant buildings - at least not most of them.  There are three categories of registered vacant buildings - Category 1, 2, and 3.

Category 1 properties are pretty simple; the new owner simply needs to register or re-register ownership, pay any outstanding fees, and comply with any outstanding orders for legal occupancy.  You probably won't be able to buy a category 3 property.  These properties are the worst of the worst, and the City of Saint Paul is demolishing most of these.  Category 2 properties are the focus of this blog.

Category 2 properties are condemned or have multiple housing violations.  If you want to buy one of these properties, you'll need to complete the same requirements for Category 1 properties, and obtain approval from the City.  Here are the basic steps:

  • Contact the City to start the approval process, and to be sure you are following the correct process for the particular property.  Call 651-266-8989 and ask for a person to talk to about a vacant building purchase, a “Chapter 33 Review”, process. This review process is free at the moment, but there will be a $275 fee for Sale Review, effective 1/1/2010.
  • Get a code compliance report. Before the property is purchased, a code compliance report must be obtained.  The cost of a code compliance inspection is $426 for a single family home, and $533 for a duplex. The City of Saint Paul is currently running about a month out on getting these reports done.
  • Provide proof the repairs will happen: Buyers need to provide proof that they'll be able to perform the code compliance repairs after they buy the house.  The buyer must submit a cost estimate for the repairs, a schedule of when the work will be completed, and must provide proof of financial ability to perform repairs.  The City of Saint Paul will accept proof of financial capability on a case by case basis.  The money for the repairs does not need to be escrowed.
  • Complete the repairs: The repairs required by a code compliance inspection aren't unreasonable.  I've read a few of these reports and talked to the city inspector that does these, and the repairs are usually pretty basic things that any good home remodeler would take care of as part of the fixing-up process.  A few of these things are replacing roofs that are shot, having proper grade around the house, correcting unsafe stairways, repairing or replacing damaged windows /  siding / trim, correcting plumbing / electrical / HVAC defects, and correcting any structural issues.

Every good contractor I know fixes all these things when buying a house with the intention of fixing it up for resale or rent.  I'm glad that the City of Saint Paul is requiring these repairs, because it prevents the stereotypical 'fix-n-flipper' from pulling their little trick (buying a run-down property, slapping some new paint on the walls, installing stainless steel appliances, and marketing the property as 'recently remodeled').  The repairs required by code compliance forces contractors to repair houses more the way they should be repaired.

  • Certificate of Code Compliance Required: All repairs must be done with permits and approved by the City, and the Certificate of Code Compliance must be issued, before the building can be occupied.

For a sample code compliance report, click here.  To obtain this report, I simply went to the Saint Paul Vacant Building List, selected "View By Category Type", chose "Category 2", and made note of an address on the list - 900 3rd ST E (this was the second property listed at the time I wrote this blog- the first property hadn't had a code compliance report generated yet).  I then went to the Saint Paul Property Lookup Page, clicked on "Property info and Permits by Address", then typed in the address that I had previously noted.  If you scroll down on the page a little bit, you'll notice a hyperlink that reads "07/24/2009: Vacant Building - Code Compliance Report (DSI)."  Click that link to pull up the report.  If you want to get a more specific idea of what items need to be addressed for code compliance, read through a few more code compliance reports.

If you’re going to take nothing else away from this blog, the most important thing to know is that you need to contact the city when buying a registered vacant building.  I can’t stress that enough.

Reuben Saltzman, Structure Tech Home Inspections - Email – Saint Paul Truth In Sale of Housing Evaluator

RELATED POSTS:

Note: the information above was reviewed for accuracy as of this writing by Connie Sandberg, Saint Paul Truth-in-Sale of Housing Program Administrator. VB Sale requirements may change at any time. Contact the City directly for the most recent and accurate information.

Some of the information in this blog was obtained from a document published by the City of Saint Paul, Requirements for the Sale of Registered Vacant Buildings

 

 

 

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

 

There’s a ton of web sites out there offering all the same basic advice on Christmas light safety; don’t use frayed cords, don’t use damaged lights, blah blah blah.  I think most people know all this stuff.  I was curious what could really pose a threat if you’re using new lights and new extension cords, so I thought I’d do a little math and figure it out.

As they say on the greatest TV show ever, WARNING: SCIENCE CONTENT.

As I see it, there are three main places for potential failure when installing Christmas lights – extension cords, power strips, and light cords.  I’m assuming the lights will be plugged in to a standard 15 amp outlet, and nothing else is running on that circuit (lighting, TVs, radial arm saws, etc).

Lights: I took a brand new string of 150 lights and examined the fine print on the warning label.  As you can see, the lights draw .54 amps.  This means that you could theoretically have 27 sets of lights plugged in to one circuit, and you would use 14.58 amps – just below the tripping point of a standard 15 amp breaker.  Each string of lights has a 3 amp fuse built in to the plug, so you could potentially have five strings of lights plugged in to each other, end to end, to get 2.7 amps.  For the record though, I’ve always heard that you shouldn’t use more than three.

Warning Label with Arrow
If you noticed the date code on the lights, you got me. These lights have been sitting in my basement for seven years. When stuff goes on clearance for 25 cents, I can't help myself!

Christmas Light Package

Power Strip: I just took a look at a cheap power strip that I had lying around in my basement, and was surprised to see that the power strip was rated for 15 amps!  This means that the power strip should be able to deal with anything I plug in to it – if I overload it, the circuit breaker in my electric panel will trip.

Extension cord: I expected this to be the weakest link, but it’s not as weak as I thought; the smallest extension cord I could find online or in the store was rated for 13 amps.  This means that if you plugged a power strip in to the end of the extension cord and ran 5 strings of lights (with 5 sets to a string), you would have a total of 25 sets pulling13.5 amps.  This could start the extension cord on fire.  Twenty-four sets of lights would probably be safe at 12.96 amps, giving you a total of 3,600 lights.
Extension Cord

The bottom line? All the blah blah blah advice you hear is right on.   As long as you’re using new lights, new extension cords and new power strips, you shouldn’t have much to worry about, and you shouldn’t have to do any math.    Just remember to read the safety labels, and do some simple calculations if you think you're using too many lights.

What if 3,600 lights isn't enough? Of course, a lot of people ask me this, and I always tell them to buy LED lights.  They're hideously expensive, but they use 80% - 90% less power.

What about the heat from the lights? Mythbusters already tried setting a Christmas tree on fire using only the heat from the bulbs.  It's impossible.  They ended up using a neon transformer to set a tree on fire.

Reuben Saltzman, Structure Tech Home Inspections – Email – Minnesota Home Inspections

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

Most homes in Minneapolis and Saint Paul are old houses with masonry chimneys.  When these masonry chimneys go bad (and they all go bad) the repair can be very expensive.  If you call up a chimney contractor to see what can be done about it, they'll tell you the chimney needs repair, just like an orthodontist will tell you your kid needs braces.  Repair is just one option. The other option is removal.

Bad Chimney

When chimneys are badly deteriorated, sometimes it just makes more sense to tear the chimney down below the roof line instead of repairing the section that sticks up above the roof.  The benefits of doing this are lower repair costs, less exterior maintenance, and less chance for leakage at the roof.  Chimneys are notorious for leaks, both through the top and at the roof flashing.

Removing Chimneys

If you're thinking about tearing a chimney down below the roof line, the chimney must be located in the middle of the house.  If the chimney is located on an outside wall, the fix wouldn't simply involve removing the chimney below the roof line - it would require complete removal of the chimney, which might be cost prohibitive.  I counted houses around my neighborhood in Minneapolis (Bryn Mawr), and about three out of four houses has a chimney in the middle of the house.

To remove the chimney below the roof line, the chimney must also be abandoned, or only be used to vent gas appliances that are connected to a metal flue liner.  If the chimney is completely abandoned, it's a no-brainer; it's not doing anything, just get rid of it.

If the chimney is being used to vent gas appliances such as a furnace /  water heater / boiler, that vent will still need to penetrate the roof to carry the exhaust gases to the exterior.  Just make sure that all of the gas appliances are properly connected to the vent!

It used to be common practice to connect the furnace to a metal vent that ran inside the chimney, while the water heater would be connected only to the chimney, where it would use the annular space around the furnace vent to carry exhaust gases to the exterior.  If you see the water heater vent connector entering the chimney separately from the furnace or boiler, this is probably what is happening.  That's what you're seeing in the photo below - the smaller vent connector that I outlined in red comes from the water heater.

Water Heater Vent Connector2

 

The diagram below shows the same thing - click for a bigger version.

 

Improper Water Heater Venting

If you have an installation that looks like this, you should have it fixed, whether you plan on tearing down your chimney below the roof line or not.  Allowing the water heater to vent in to the annular space in the chimney will allow the corrosive exhaust gases to damage the chimney walls, and water heaters usually don't draft properly when they're installed this way... but I digress.  More on this topic another day.  Back to the chimney.

If the chimney is removed down below the roof line, be sure to seal up what's left of the chimney inside the attic space, to prevent the chimney from doing what it does best - bringing warm air up!  If the chimney ends below the roof line, it will act like a huge attic bypass, allowing heat to escape in to the attic.  If the chimney is abandoned, seal off the top completely.  If the chimney is still used as the chaseway for a gas vent, seal off the area between the chimney and the vent with sheet metal, and use high-temperature caulking to make it airtight.

No more chimney maintenance!

Reuben Saltzman, Structure Tech Home Inspections – Email – Bryn Mawr Home Inspections

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

For the last 800 years, building codes have allowed bathrooms to be built without exhaust fans.

Exhaust fans aren't even a requirement here in Minnesota!  This is a great example of how building codes are only minimum standards. I thought about this while doing a home inspection at a rental home in Minneapolis.   The outdoor temperature was about 45 degrees, and every single window in the home was covered with condensation, which was also dripping down the walls.

Condensation on a window in Minneapolis

Oh, and there were no fans installed.

Bathrooms need exhaust fans to help eliminate moisture problems, plain and simple.  When people take showers and baths, moisture gets pumped in to the air.  During the winter, this moisture condenses on windows and walls, and often makes it's way in to the attic space through attic bypasses, where it will create frost.

Minnesota requires windows in bathrooms that provide a total glazed area of at least three square feet, and half of that must be openable.  The exception to this rule comes when a bath fan is installed that will exhaust at least 50 cubic feet per minute, or a continuous exhaust system such as a Heat Recovery Ventilator exhausts at least 20 cubic feet per minute.

The idea of someone actually opening a window on a cold winter day in Minnesota to help reduce moisture in the bathroom is ridiculous.  If you live in a house without an exhaust fan in a bathroom that gets used for showers or baths, install one.  Your house will thank you for it.

If you're going to install a fan, here are a few tips to make sure your house is happy with the fan.

  • Choose a good fan. You'll want to balance noise level, performance, and price.  If you buy a cheap noisy fan, you probably won't even want to turn it on.
  • Make the exhaust duct short. A proper exhaust duct will be as short as possible and take as few turns as possible.  The longer the duct and the more twists and turns it takes, the less air flow.  A fan rated for 80 cubic feet per minute (CFM) assumes the fan has no duct.  As soon as a duct gets added, the actual CFM goes down.  I've inspected hundreds of houses where there is barely any air flow at bath fan exhausts.  If the bath fan is located in the basement and the duct runs up to the roof at the second story, air flow will be pretty pathetic.
  • Waterlogged Duct Insulate the duct where it passes through unconditioned spaces, such as the attic.  If you don't, moisture will condense it the duct, and might drip down and stain the ceiling. I once inspected a house in Richfield where the exhaust duct was uninsulated in the attic, and so much moisture had accumulated in the duct that it was completely filled with water!  The photo at right shows me holding my flashlight up against the duct - this is one of my favorite photos ever.  Click the thumbnail to see the full version.
  • No Switch Don't use a standard switch to control the fan. When a single switch controls the fan, people turn the fan on while in the shower or maybe after the shower, and turn the fan off when leaving the room.  The problem is that the fan doesn't run long enough to remove enough moisture.  A better solution would be to install a timer that runs for at least a half hour, or install a humidity sensing fan.

Reuben Saltzman, Structure Tech Home Inspections – Email – Minneapolis Home Inspections

RELATED POSTS:

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

Last week I gave an overview of what GFCI outlets are for - the long and short is that GFCIs are life safety devices; they prevent lethal shocks.  This week I'll talk about the different types of GFCI devices, how to test them, what drives me crazy with them on home inspections, and what some of the newer features are.

The two most common types of GFCI devices are circuit breakers and outlets.  A GFCI circuit breaker gets installed at the electric panel, and protects the entire circuit.  This is a handy way to make sure everything on the circuit gets protected, and there is no need for individual GFCI outlets anywhere in the circuit.  The other type, which everyone has already seen, is an outlet.  The most common type of outlet is a duplex receptacle, which is shown below left.

GFCI Outlet GFCI Breaker

One GFCI outlet can protect several other non-GFCI outlets when wired properly.  Every GFCI outlet has screws behind the outlet labeled "line" and "load".  The current coming in to the outlet must always be connected to the "line" side of the outlet.  If more outlets are going to be protected by the GFCI, they can be wired to the "load" side of the outlet.   Many houses built in the eighties will have the exterior outlets, garage outlets, and basement bathroom outlets wired downstream from a GFCI outlet in the upper level bathroom.  Today it's common for a GFCI outlet at the kitchen countertop to protect several other outlets.  This saves money.

GFCI Outlet Protection
A redundant way to wire  GFCI outlets is to wire one GFCI downstream from a second GFCI outlet.  This is wasteful, pointless, annoying, and it makes things difficult for the home inspector and anyone else that might trip the outlet, especially if the first GFCI outlet is hidden! Please don't do this.

GFCI outlets should be tested every month because they can go bad, and a defective GFCI outlet doesn't provide any life safety protection.  To test a GFCI outlet or circuit breaker, simply press the test button.  Here are the possible outcomes you can have by testing a GFCI outlet with the test button:

  • Acceptable - The reset button pops and the power goes off.  The GFCI device is functioning properly.  Simply press the reset button to restore power.
  • Unacceptable - The reset button doesn't pop.  This means the outlet is defective and should be replaced.
  • Lock symbol on a SmartLock GFCI outlet Unacceptable - The reset button pops but the power doesn't go off.  This means the line and load are reversed at the outlet. This should be corrected.  Newer "SmartLock" GFCI outlets that have a little lock symbol on the front have a built-in safety feature that prevents the outlet from getting energized if it's incorrectly wired.
  • Unacceptable - The reset button is already popped, the power is off, and the reset button won't go in.  This can happen on the newer "Smartlock" GFCI outlets if they're improperly wired or the outlet has gone bad.
  • Acceptable, but annoying - The outlet loses power when tested, but the reset button doesn't move.  This means someone wired the GFCI outlet downstream from a second GFCI outlet.  Shame on them.

GFCI TesterAnother way to test GFCI outlets is to buy a tester.  This is a great way to test standard outlets that are wired downstream from a GFCI device.  Just plug it in to an outlet and press the test button.  If the power goes out, the GFCI device is working properly.  If the power stays on, it doesn't mean the GFCI device is defective - sometimes GFCI testers won't trip GFCI outlets.  If this is the case, try the test button at the outlet.

Why do GFCI outlets go bad? I honestly don't know, and if anyone reading this blog can tell me, I'd be interested in hearing about it.  From my own experience, I've found that after a GFCI outlet has had a lot of power running through it, it will often fail.  For example, any time I'm working on a remodeling project and I'm running a bunch of power tools through a GFCI, it goes bad within about a month.  I've heard of home builders wanting to put all of their GFCI outlets on the inside of the house because there's this idea that cold Minnesota weather makes GFCI outlets go bad, but I haven't experienced that myself, and a study on GFCI outlets has shown that temperature doesn't have any effect.

RELATED POST:  GFCI Outlets, Part One

Reuben Saltzman, Structure Tech Home Inspections – Email  Home Inspector in Minneapolis

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

For this this week and next week's blogs, I'll be waxing on GFCI outlets.  I'll talk about what they do, why they're so important, what you need to know about them, and how to test the outlets in your own home.  GFCI Outlet

First, a quick refresher. In my blog about reversed polarity outlets, I explained that there are two wires that conduct current - one get connected to the earth (grounded) and the other doesn't.  The grounded conductor should always be white, and is referred to as the "neutral" wire.  The ungrounded conductor is usually referred to as the "hot" wire, and it can be any color besides white or green, but it's typically black.  Because the neutral wire is connected to the earth, any time you're in contact with the earth and you touch an ungrounded wire, you'll complete the circuit and you'll get a shock.  The general, technical name for this event is a ''ground fault", because current is getting back to the ground in a way that it shouldn't (it's using you!).

Not all shocks are the same. Here's where we'll get in to a little more detail about what happens when a human comes in contact with an ungrounded (hot) conductor.

  • No shock. If I could magically levitate and grab on to a ungroundedconductor, I wouldn't get a shock.  I'm not providing a path back to the earth, so the electricity doesn't have anywhere to go.  This is why birds can sit on power lines without getting a shock.  No ground fault.
  • Small shock. If I were working on the second story of my wood-framed house, wearing rubber soled shoes, standing on the carpet, and then came in contact with an ungrounded conductor, I would probably receive a relatively mild shock.  The current has a difficult time traveling through my skin, through my body, through my shoes, through the carpeting, through the wood framing in the house, and eventually back to the earth.  I say 'relatively' mild because this has happened to me several times, and I'm still here to tell about it.  It still hurt like hell every time, and it's always dangerous. This is a ground fault.
  • Severe / lethal shock. If I were holding on to the kitchen faucet with a wet hand and I touched an ungrounded conductor with my other hand, which was also wet, I'd probably get killed.  Having a wet hand will make it easier for electricity to pass through my skin.  After the electricity passes through my body, it has a very easy time getting back to the earth; it will pass through the kitchen faucet to the water pipes, which are directly connected to my electric panel.  This ground fault could easily be enough to kill me.

To prevent lethal shocks through ground faults, special electrical devices called Ground Fault Circuit Interrupters, or GFCIs, are required in homes.  If a GFCI device detects a ground fault, it will shut off (or 'interrupt) current within a fraction of a second.  It won't be fast enough to prevent a painful shock, but it's enough to keep you from getting killed.

GFCI devices were first required near swimming pools in 1971.  Today they're required in all the areas that lethal shocks are most likely to happen - typically at areas that are wet and have good contact with the earth.  These areas include the exterior, garages, kitchen counter tops, bathrooms, unfinished basements, crawl spaces, and outlets within 6' of laundry sinks, utility sinks, and wet bar sinks, among other places.  For an excellent one-page chart that lists all the locations and shows when the specific requirements went in to effect, click here.

That's enough information on GFCI's for this week.  Next week I'll talk about the different types of GFCI devices available, the difference between new and old GFCI outlets, how to test them, how they irritate me, and how to save money while installing them.

Reuben Saltzman, Structure Tech Home Inspections – Email  Home Inspector in Minneapolis

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

10.  Tree Branches Rubbing On The Roof  Tree branches do a lot of damage to roofs.  Just think about branches rubbing on the roof all day long while the wind is blowing.  This adds up to a lot of damage.  Tree branches too close to the roof will also give squirrels, raccoons, and other pests very easy access to the roof.

9.  Double-Tapped Circuit Breakers  Every circuit breaker in the main panelboard should have only one wire connected to it, unless the circuit breaker is designed for more than one wire.  Most aren't.  Sometimes the fix for this defect is very quick and easy, sometimes it's a major project.

8.  Bath Fans That Don't Exhaust Properly I start my home inspections by turning on every fan in the house, and I make sure that air gets exhausted to the exterior.  I find a ridiculous amount of fans that make plenty of noise, but don't move any air.  The problems can be caused by disconnected ducts, ducts that aren't continuous to the exterior, blocked internal dampers, stuck external dampers, or kinked ducts.  A bath fan exhausting in to the attic is always the worst.

7.  Missing / Improperly Located Smoke Detectors  Smoke detectors should be present in a common area on every level and in every bedroom, and the installation instructions need to be followed.  I can't tell you how many smoke detectors I see tucked away in to corners - this is never an acceptable installation, because smoke won't get there fast enough.  

6.  Missing Cover Plates  Missing or broken cover plates at outlets and switches are shock hazards, period.  Common problem, easy fix.

5.  Improperly Wired Outlets  Ungrounded three-prong outlets and outlets with reversed polarity are very common defects.  These are shock hazards.  You can check the outlets in your own home with an outlet tester that costs about five dollars.

4.  Missing Carbon Monoxide Alarms.  Minnesota requires carbon monoxide alarms within ten feet of every sleeping room.  Lots of people put them in the same room as the heating plant; that's fine, but it's not required.

3.  Poor Water Management  This consists of the same thing every time - negative grading and improper downspout extensions.  This is almost always the cause of wet basement and foundation problems.  The grading around the house needs to slope away, and downspout extensions should take water well away from the house.  Improper downspout extensions are worse for the foundation than no gutters at all.

2.  Missing Anti-Tip Devices At Ranges  Ranges have been sold with anti-tip brackets since 1991, but it's pretty rare for me to find the brackets installed.  These are required to prevent ranges from tipping over, which could cause serious injury or death to a child.

1.  Attic Bypasses  I find these all over the attic on almost every old house I inspect.  Attic bypasses allow conditioned household air to leak in to the attic space, and they can reduce the effectiveness of insulation by as much as 70%.

Reuben Saltzman, Structure Tech Home Inspections - Email - Minnesota Home Inspections 

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 

Summer is gone, fall is here, and it’s time to get around to all the fall chores – put up your storm windows, turn off the outside sillcocks, cover up the air conditioner… wait, scratch that last one.  Don’t waste your time or money installing a cover on your AC unit.  I’ve already seen people start to cover their air conditioners this year, but there’s no need to.

Air Conditioner Cover

Why do people even install air conditioner covers?  One company that sells covers claims that their AC cover “protects from dirt, hail, snow, ice, nesting animals, moisture, bitter cold, and harsh sunlight.”  Wow, that list makes me not want to go outside.  Let’s review those one at a time.

  • Dirt – When the fan on an AC unit is running, air will be sucked in on all sides of the unit, and this is when most dirt and dust accumulates.  When the unit is just sitting dormant, outdoor contaminants don’t get sucked in.
  • Hail – We don’t get hail during the winter here in Minnesota.
  • Snow – Snow won’t hurt the AC unit.
  • Ice – Ice won’t hurt the AC unit.
  • Nesting Animals – I’ve never seen this happen, and I can’t figure out how it could.
  • Moisture – C’mon, seriously?
  • Bitter Cold – Get out.
  • Harsh Sunlight – Ok, that’s enough.

AC units are designed to be installed outdoors all year ’round.  They are designed to hold up to the elements – they don’t need a cover.  The manufacturers have already taken things like ‘harsh sunlight’ in to account.  If you need proof, just check the web sites of some of the larger manufacturers, such as Rheem and Lennox.  They specifically say their units shouldn’t be covered, because the covers can trap moisture, which can cause damage to the unit.

If you want to keep stuff from falling in to the top of your air conditioner during the fall, just put something on top of it, like a piece of plywood.  While it seems a little laughable, even a makeshift cover like the one pictured below will work just fine, as long as you do something to keep it from blowing off.  This will keep debris from falling in the top of the unit, and it won’t trap moisture.  If you want something that doesn’t look silly, install a very short cover.

Makeshift Air Conditioner Cover

Reuben Saltzman, Structure Tech Home Inspections – Email  Wayzata Home Inspections

 

Reuben Saltzman, Structure Tech Home Inspections - Email - Minneapolis Home Inspections

Structure Tech Home Page     Structure Tech Facebook Page     Reuben's LinkedIn Page     Follow StructureTech on Twitter     ASHI Certified Home Inspector - Click To Verify     Click to subscibe to Reuben's Blog

 
 
Dsc_5314 Rainmaker_large

Minneapolis Home Inspections - Reuben Saltzman

Minneapolis, MN

More about me…

Structure Tech Home Inspections

Office Phone: (952) 915-6466

Cell Phone: (612) 205-5600

Email Me

Home inspection topics in the Minneapolis / Saint Paul area. Clicky Web Analytics

Clicky



Links

Archives

RSS 2.0 Feed for this blog

Find MN real estate agents and Minneapolis real estate on ActiveRain.