Build a House (av)(aw)

By
Home Inspector with Elliott Home Inspection

With the foundation wall up it is time for the start of what it will be supporting.

This is a wood frame platform style construction so in order to begin they need to attach it to the foundation wall.

This is accomplished by bolting the bottom of the frame, to the cemented in place anchor bolts.

This is called the sill plate.

Notice how the wood of the sill plate is not allowed to make direct contact with the cement.This is done by placing a foam sill gasket in between.The foam comes in rolls that remind you of a big roll of tape.100 feet each in this case.

When looking at the picture you will see extra space,as the brick veener will sit here.More on brick veener later.

sill platesill plate

Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

It is going to be brick veneer.and the comments are appreciated as I personally have never tried this before and often dumbfounded on what would make good captioning.

More than likely I will go back once in a while and put them all together in PDF from the beginning to create a smooth flowing storyline based on these comments.

Should I stick to photos or would their be some kind of way to give you guys credit for comments with a link to your sites as that would be the Active Rain way of doing things.

May 28, 2007 05:22 AM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

By the way the brick is sitting in the front yard for the last couple of weeks due to a carpenter problem.

These guys were fast as lightning,but there were issues with some of the workmanship,

As for myself,I have been busy trying to think up ways of increasing business now that I am trying to make this a full time gig.

So far I have never stepped foot in a Real Estate office and have been relying on internet leads which is just keeping my head above water.

The cool thing is my job tomorrow the guy said he read a good review on my service at Goggle.

Where did he see this as I was not aware people were rating me.?

My next step is going to be a dip into Guerrilla marketing.

I will let you guys know what works and what does not.

May 28, 2007 05:41 AM
Robert Cramer
Five Star Property Inspections - Belleville, IL

Hey Bob,

I use a lot of the Guerrilla marketing ideas.  I also market to realtors, but having a great web presense is key also.  I wish you the best of luck in you marketing efforts.  Should you have any questions about anything please feel free to call me or send me a note, I would be happy to help. 

Lately I have been marketing to mortage company's and banks doing draw inspections.  I also target new constructin phase inspections relying less and less on realtor referrals.  I have also been doing a lot of marketing to new construction warranty inspections.  Hope this helps a little. 

I think what you are doing with the series is great, keep up the good work.

May 29, 2007 01:35 AM
Scott Patterson, ACI
Trace Inspections, LLC - Spring Hill, TN
Home Inspector, Middle TN
Back to treated wood: Don't forget that the foundation bolts need to be either stainless or the HDG type, or they will corrode over time.  I would say that 80% of the new homes I'm inspecting they have neither and most are already rusting.
May 29, 2007 01:56 AM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection
Scott since the bolts are embedded what would be the fix ?
May 29, 2007 04:05 AM
Scott Patterson, ACI
Trace Inspections, LLC - Spring Hill, TN
Home Inspector, Middle TN

That's the beautiful part of being a home inspector, we don't have to design the corrections or repairs!

I would suppose that the only way to properly take care of improper foundation bolts would be to replace them.  Logic tells me that one would do it the same way one would add foundation bolts.  A hole is drilled through the sill plate and into the concrete slab or wall.  Then the proper threaded bolt would be set in the hole with and epoxy designed for concrete and metal bonding.  But none of this should be done without it first being designed or approved by an engineer or the architect who is over the project.

May 29, 2007 07:38 AM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

Sounds like an awfully expensive fix for them to be doing it wrong 80% of the time.

 

May 29, 2007 08:21 AM
Scott Patterson, ACI
Trace Inspections, LLC - Spring Hill, TN
Home Inspector, Middle TN

The cost of the repair and the fact that it is seldom done has little to do with the builder correcting it.  All I can do as an inspector is to report the problem.  The only time an inspector will see this is if the drywall is not up or the walls are open, unless it is a crawl space. 

I see most of them while I'm doing draw inspections for banks, and the banks are only looking (and paying) for percent complete not quality.

May 29, 2007 08:36 AM
Robert Cramer
Five Star Property Inspections - Belleville, IL

Anchor Bolts (right angle bend)


Stock Sizes - ASTM A307 grade C / F1554 grade 36 / F1554 grade 55
100% domestic with chemical and physical test reports .

Anchor Bolt Size

Plain Finish

Hot Dip Galvanized

1/2 x 8 x 2 x 4

1/2 x 10 x 2 x 4

1/2 x 12 x 2 x 4

1/2 x 18 x 4 x 4

 

5/8 x 8 x 2 x 4

5/8 x 10 x 2 x 4

5/8 x 12 x 3 x 4

5/8 x 18 x 3 x 4

 

3/4 x 6 x 3 x 4

3/4 x 8 x 3 x 4

3/4 x 10 x 3 x 4

3/4 x 12 x 3 x 4

3/4 x 14 x 4 x 6

3/4 x 15 x 4 x 6

3/4 x 16 x 4 x 6

3/4 x 18 x 4 x 6

3/4 x 20 x 4 x 6

3/4 x 22 x 4 x 6

3/4 x 24 x 4 x 6

3/4 x 30 x 4 x 6

3/4 x 30 x 4 x 7

 

7/8 x 10 x 3 x 4

7/8 x 12 x 3 x 4

7/8 x 18 x 4 x 6

 

1 x 12 x 4 x 4

1 x 16 x 4 x 6

1 x 18 x 4 x 6

1 x 24 x 4 x 6

1 x 36 x 4 x 6

1 x 36 x 4 x 7

 

1-1/4 x 32 x 6 x 7

1-1/4 x 36 x 5 x 6

1-1/4 x 42 x 6 x 7

Black - Indicates stock ASTM A307 grade C
   and F1554 grade 36 items.
Red - Indicates stock ASTM F1554 grade 55 items.

 

STOCK

Portland Bolt manufactures and stocks the above list of anchor bolts, which are available for immediate shipment.

MANUFACTURING

Portland Bolt manufactures custom bent anchor bolts from 3/8" - 4" diameter to virtually any ASTM specification. They are provided either plain finish or hot dip galvanized. Stainless steel anchor bolts are also manufactured. All operations, including the galvanizing process , are performed in-house.

APPLICATION

Anchor bolts are imbedded in concrete and used to support structural steel columns, light poles, highway sign structures, bridge rail, equipment, and many other applications.

RELATED LINKS

Anchor Rods
Swedged Rods
All Thread Rod
Wilson Anchor Sleeves
Anchor Bolts for California Schools

May 30, 2007 01:32 PM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

Thanks Robert ...I may need the help soon as I have no experiance with marketing

The internet is bringing some business but not enough to stay afloat and I will never be reduced to being a putz begging at a Real Estate office.Here have another donut,while I use psycology to convince you I will pass all your homes with a gold star ,give you payoffs and kiss your butt you wonderfull good looking intelligent master of all salespeople.Yech!

The other avenues you mentioned may be more palatable.

 

May 30, 2007 05:38 PM
Robert Cramer
Five Star Property Inspections - Belleville, IL

While I do market to realtors, I do not beg.  I also make it clear that my report is in the best interest of the client and will never be a fluff report.  Believe it or not some realtors respect this and some do not.  I am only looking for the honest reputable realtors that want a great inspector.  You can market to realtors and still hold your head up high, just find the ones who respect what you do and want whats in the best interest of the client. 

As far as the rest of the marketing, Have you tried banks and title company's? 

May 31, 2007 03:28 AM
Steven Turetsky
Comprehensive Building Inspections & Consultants - Staten Island, NY
Building Moisture Analyst

I don't go into RE offices either. I think that is a waste of time. I do speak to people every day and always find ways of letting everyone know what I do. You never know when your services are needed or can be recommended.

Sometimes, I'll spend a couple of hours on a Saturday or Sunday stopping by some open houses. Not to beg or bribe. I just introduce myself, sometimes chat a bit. If they like me or my personality, perhaps they will recommend me. Perhaps another day I will meet them elsewhere. At some point, when they think of a Hone Inspector they may think of me.

Why didn't anybody mention the spacing of the foundation bolts? OK, who knows the answer?

And since your talking brick shelfs, then also mention that the ends of the beams should be fire cut. Meaning the top of the joist that is buried in the masonry has to be cut back, so in the event of a fire it allows the beams to drop out when they burn... so the building will "fall in" and not "fall out". There should also be ties at the ends of the beams into the masonry to keep the building from bulging out. I usually make my own by weld a "T" out of 1/2" square steel stock. I drill two holes on the straight end to attach to the beam and bury the "T" end into the bricks/blocks.

Since the treated lumber is no longer made with arsenic, can it be used for more than the first layer of lumber.

May 31, 2007 02:08 PM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

Hi Steve..Just tried to send you a private message but it did not go through,so I will try agaim tomorow.

To answer your question about sill bolts ,anchor bolts,or as you called them foundation bolts,they should be spaced 6 feet apart and 12 inches from ends.

The rest I will let you educate as it is to late for me to research.

May 31, 2007 05:19 PM
Scott Patterson, ACI
Trace Inspections, LLC - Spring Hill, TN
Home Inspector, Middle TN

On anchor bolts:

Bob, you got part of it right. 

The requirement for building/homes over two stories is every 4 feet.  And all require them to be no less than 1 foot from the corners.  So you start in the corner and space them out either 4' or 6'.   This is from the IRC so it might be different in areas that do not use the IRC.  I'm betting that the Florida Building Code is completely different.  Maybe Mitchell can chime in.

Jun 01, 2007 11:27 AM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection
Ok Smarty pants..He did not specify over 2 stories.
Jun 01, 2007 11:54 AM
Steven Turetsky
Comprehensive Building Inspections & Consultants - Staten Island, NY
Building Moisture Analyst

Florida's building code is different. I think the insurance companies had a lot to do with that. I think they got tired of their houses blowing away. 

Bob, What do all the abbreviations (aw), (ag), etc. stand for?

What's for dinner tonight?

Or are you spending the evening out. You had better behave yourself!

Jun 01, 2007 12:09 PM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

Oh I guess I figured every one would catch on.

With so many photos that is my way of numbering them.aa ab ac ad

As a frusteraated artist I have to many and need to start storing them before this laptop runs out of memory.

I may go out for a little ,but here in the city we have alot of fairs going on this weekend.

I am not doing as much this summer as in years past.Getting old sucks.

Between reading the boards I am experimenting with a blog and a wiki as a means to start that special boiler plate thread we disscused.

Everything takes longer when you do not have the formal training.

Sometimes I feel it is an advantage to not know limitations however.

I have so many links I may publish them .

Jun 01, 2007 04:00 PM
Steven Turetsky
Comprehensive Building Inspections & Consultants - Staten Island, NY
Building Moisture Analyst

I figger'd it was some type of "filing" system, but I didn't see a pattern and was a bit confused.

My weekend is non stop too. I have to work today, this was a surprise, but I have to install a piece of lami at UCP in Manhattan. I was hoping to work on my boat, maybe I'll still get in a couple of hours. Sunday my son starts football camp, his first time, and I volunteered to help, so now I am a "football dad".

Getting old is a bit frightening at times and it can be depressing at others, but it sure beats the alternative. As far as limitations go, I'll bet you're just complaining out loud. I don't think you are the type of guy has has any limitations.

As far as all those links are concerned, buy a bag of onions, a bushel of peppers and open a stand at one of those fairs that are going on. You'll probably meet some young chick there and you can show her your blog and wiki.

Jun 01, 2007 10:19 PM
Bob Elliott
Elliott Home Inspection - Chicago, IL
Chicago Property Inspection

Several years aga I actually did a few art fairs and may do so again as it is in my blood to create.

I go to many fairs and festivals in my constant search for something new and different to inspire me.

Good luck with your boat,There is nothing like the smell of the fresh air,and feeling you get looking back at the shore.

In Chicago we often go out ,anchor,and swim off the boats.

Is this something you are able to do there,or is the water to cold?

Jun 02, 2007 05:02 AM
Steven Turetsky
Comprehensive Building Inspections & Consultants - Staten Island, NY
Building Moisture Analyst

The water is fine, although I don't like swimming in the harbor. We do have a few favorite spots. We also like to fish a bit and simply going for a ride is relaxing. Especially at night.

I also enjoy the boat without even leaving the dock. I shut the door, close the shades and turn on the air conditioning. The peace and solitude are like medicine to me. The only time I ever oversleep is when I stay on the boat. The gentle rocking is so relaxing.

Jun 02, 2007 06:15 AM