Sometimes I take great pictures, and sometimes I don't, I guess that's why I'm not a photographer.  Anyhow, let me describe the picture below a little bit before I get too far:

At the bottom right hand corner of the picture is a chimney on top of a garage conversion to living space.  The garage is about 9-ft. from the window at the top of the picture at the house.  And as it looks in the picture, the chimney is lower than the window.

 Okay, do you see any problems with that?

chimney picture by Pillar To Post a Corona home inspection company

The chimney needs to be a minimum of 2-ft above any part of the building within 10-ft and at least 3-ft above any part of the roof within 10-ft.  Therefore the chimney will likely cause that nice smokey aroma in the room that has the window in the picture.  I guess that's nice if you like that cabin feeling during the ice-cold winter.  But then again, most people don't want to breathe smoke.  In other words, without being sarcastic, this is a health and safety concern.

 

I hope this gives you a little more information about a professional home inspection and its value.  Be safe out there.

 

Posted by Joseph Lang of Pillar To Post Professional Home Inspection

PTP logo          ASHI          NAHI

Pillar To Post Home Inspection

(c) 2009 Joseph Lang dba Pillar To Post

 

Pillar To Post is your local franchise providing home inspections for clients and real estate professionals located in Rancho Cucamonga, Upland, Montclair, Chino, Chino Hills, La Verne, Claremont, San Dimas, Glendora, Azusa, Diamond Bar, Brea, Fullerton, Placentia, Fontana, Rialto, Corona, Norco and surrounding areas.

 

 
Post is included in group: SO CAL Pass Area Communities and other Interests
Post is included in group: South Bay Realtors
Post is included in group: Independent Thinking Inspectors
Post is included in group: Home Inspectors across the country
Post is included in group: Ask the Home Inspector

2 Comments on Smokin' it up (A Home Inspection Blog)

SEP
23

What's worse is when the furnace flue under a window!  Some people just don't think!

 

-

8:27am • #1
NOV
03

At least they could do is to put a spark arrestor on it huh?  I've seen many h/w heater venting under the eaves in my day.  I'm taking notes here.

3:28pm • #2

Leave a response…



(optional)
What does the graphic say?
 
Ptp_award_1 Rainmaker_large

Joseph Lang - Southern California Home Inspector

Rancho Cucamonga, CA

More about me…

Pillar To Post Professional Home Inspection

Address: Rancho Cucamonga, CA, 91701

Office Phone: (909) 989-5114

Email Me

Meez 3D avatar avatars games Get the Home Inspection Vidoe - inspectorjoe1's Channel widget and many other great free widgets at Widgetbox! Not seeing a widget? (More info)


Links

Archives

RSS 2.0 Feed for this blog

Find CA real estate agents and Rancho Cucamonga real estate on ActiveRain.