Oregon's Smoke Alarm Law: A Refresher

By
Home Inspector with Pillar To Post

I thought it might be helpful for buyers, sellers and agents in Oregon if I posted some information on smoke alarms.

I've been amazed at how many homes still do not have the kind of smoke alarms required by Oregon law when a house is sold and many of these homes have sold two or three times since the law went info effect in 2002.

Oregon State law (ORS 479.260) requires that when you sell your home, all smoke alarms must meet the following requirements.

All Ionization smoke alarms must have a hush feature and if solely battery powered must also have a ten-year battery.

 

SMOKE ALARM Questions & Answers  from the State Fire Marshal

Why should my home have smoke alarms?

 Most fire deaths are caused by smoke - not flames.

Most fire deaths and injuries occur between midnight and 8 a.m. when people are asleep.

Seconds count! You have approximately three minutes to escape a house fire.

The earlier a smoke alarm alerts you to a fire, the more likely you will get out alive.

What is the difference between smoke alarms and smoke detectors?

Smoke alarms are self-contained, single or multiple-station smoke-sensing devices.

Smoke detectors are smoke-sensing devices that are not self-contained. Smoke detectors operate as part of a central control system.

What is the difference between ionization and photoelectric smoke alarms?

Ionization smoke alarms are quicker at sensing flaming, fast moving fires

Photoelectric smoke alarms are quicker at sensing smoldering fires

What are the requirements for the location of smoke alarms?

Outside sleeping areas

On each level

On the ceiling at least four inches from the nearest wall or high on a wall, 4 to 12 inches from the ceiling

Meet the applicable requirements of the State Building Code at the time of construction

Are smoke alarms required to be installed in all bedrooms?

If required by State Building Code at the time of construction or remodel.

Note: Some local ordinances have additional requirements. Check with your local building department and/or housing agency.

However, the Office of State Fire Marshal encourages installing smoke alarms in all bedrooms for increased protection

Where should smoke alarms not be installed?

Kitchens

Bathrooms

Garages

Unheated areas (where moisture, frost, cooking vapors and exhaust fumes could cause the unit to sound a false alarm)

What about 110 v (hard-wired) smoke alarms?

All ionization only smoke alarms not connected to a commercial fire alarm system, whether 110 volt (hard-wired) or solely battery operated, need to have a hush feature

Only ionization smoke alarms, that are solely battery powered must be sold with a ten-year long life battery

Can 110 v (hard-wired) smoke alarms be replaced with solely battery operated smoke alarms?

No

Alarm Types

Ionization smoke alarms: Contain material that ionizes the air, making an electrical path. When products of combustion enter the alarm, the molecules attach themselves to the ions. The change in electric current flow triggers the alarm. All ionization only smoke alarms sold in Oregon are required to have a hush feature. If that alarm is solely battery powered, it is required to have a long life battery designed to last ten years.* (ORS 479.297) Ionization smoke alarms have one of the following on either the front or the back of the alarm:

 A lower case letter "i"

The word "ionization"

The phrase "contains radioactive material"

A "fan-looking" symbol

Photoelectric smoke alarms: Contain a light source and photocell, which is activated by light. Light from the bulb reflects off the smoke particles and is directed towards the photocell. The photocell is then activated to trigger the alarm. Photoelectric smoke alarms are exempt from the ten-year battery and hush feature requirements. Replace the 9 volt battery at least once per year.* Photoelectric smoke alarms have one of the following on either the front or the back of the alarm:

A capital letter "P"

The word "photoelectric"

The phrase "photoelectric technology"

Hard-wired smoke alarms with battery back-up: These alarms are wired directly into the homes electrical system. They do not require a ten-year battery. Replace the 9 volt battery at least once per year.*

Hard-wired smoke alarms without battery back-up: These alarms are wired directly into the homes electrical system. If the electrical power to the home fails, the alarms will not function.*

· Combination or dual sensor smoke alarms: Ionization and photoelectric technology in one alarm to sense flaming and smoldering fires.* These alarms have one or more of the following on either the front or back of the alarm:

May use the words "photo & ion"

A capital letter "P" and lower case letter "i"

The words "photoelectric" and "ionization"

The phrase "photoelectric technology"

The phrase "contains radioactive material"

Ionization Smoke/Carbon monoxide alarms: Activated by smoke or carbon monoxide. Replace the 9 volt battery at least once per year.** These alarms have one or more of the following on either the front or back of the alarm:

States "Smoke and Carbon Monoxide Alarm"

A lower case letter "i"

The word "ionization"

The phrase "contains radioactive material"

Photoelectric Smoke/Carbon monoxide alarm: Activated by smoke or carbon monoxide. Replace the 9 volt or double AA batteries at least once per year.**

States "Smoke and Carbon Monoxide Alarm"

A capital letter "P"

The word "photoelectric"

The phrase "photoelectric technology"

Photoelectric Smoke/Carbon monoxide with voice: Activated by smoke or carbon monoxide. Speaks the type and location of danger in your home, when programmed. Replace the 9 volt or double AA batteries at least once per year.**

States "Smoke and Carbon Monoxide Alarm"

A capital letter "P"

The word "photoelectric"

The phrase "photoelectric technology"

Explosive Gas & Carbon monoxide alarm: Activated by carbon monoxide, propane or methane gas. Replace the 9 volt or double AA batteries at least once per year.**

States "Smoke and Carbon Monoxide Alarm"

A capital letter "P"

The word "photoelectric"

The phrase "photoelectric technology"

Visual (strobe light) and tactile (shaker): For people who are deaf or hard of hearing. Replace the 9 volt or double AA batteries at least once per year.*

How often do I replace my smoke alarm?

* National Fire Protection Association National Fire Alarm Code 72-10.4.7 "Replacement of Smoke Alarms in One- and Two-Family Dwellings. Unless otherwise recommended by the manufacturer's published instructions, single- and multiple station smoke alarms installed in one- and two-family dwellings shall be replaced when they fail to respond to operability test, but shall not remain in service longer than 10-years from the date of manufacture." (Adopted as part of the Oregon Fire Code 2007 Edition, October 2007. (10.4.6))

** Carbon monoxide/Smoke Alarm combinations are recommended to be replaced 5-years from date of manufacture.

How do I keep my smoke alarm working?

Test smoke alarms monthly

Vacuum smoke alarms regularly to remove dust and cobwebs

Never disconnect or remove smoke alarm batteries for other use.

Determine alarm type. Replace alarm or battery based on the "Alarm Type" and "How often do I replace my smoke alarm?" sections. Please see above sections

What do I do if my smoke alarm goes off and there is a fire?

Get out and stay out. Never go back inside for people or pets

Get low and go under the smoke to your way out

Feel the knob and door before opening a door

Call the fire department from outside your home

What do I do if my smoke alarm goes off and it is a false alarm?

Do not disable smoke alarms when activated by cooking or other non-fire causes

Use the smoke alarm's hush feature if available

Open windows and doors to clear smoke from your home

For more information Oregon's smoke alarm law, visit: http://www.oregon.gov/OSP/SFM/CommEd_SA_Program.shtml or call 503-934-8228.

 

Posted by

Chris Livingston

Owner/Oregon Certifed Home Inspector

Pillar To Post

www.PillarToPost-PortlandWestSide.com

Click here for a List of potential Specialty Contractors

P.S. Any client of ours has open access to the Sears Commercial Center for "contractor" prices on everything from TV's to washers etc and on all brands (Bosch, LG, Kitchen Aid - not just Kenmore). Discounts of 5% to 50% from regular store prices are offered exclusively through their commercial group. This is a fantastic opportunity for our clients who may need something for the new home. Call (503) 624-3481 and ask for James Shufelt for details. Be sure to mention the Pillar To Post customer number CU071473

Inna Ivchenko
Barcode Properties - Encino, CA
Realtor® • GRI • HAFA • PSC Calabasas CA

 According to the National Fire Protection Association (NFPA), there were more than 358,500 home fires per year from 2011-2015, so it is quite important to have your smoke alarms functional. 

Oct 25, 2017 12:32 PM