This is a form that is ery comprehensive. I have used it as a contractor for inspections for my investor clients and rehabbers. This is similar to a NAHI approved inspection in all the areas that are listed
General information
1 Inspector: ____________________
2 Structures inspected: __________________________________________________
3 Type: 1 / 2 / 3 / 4 / Condo / Mfg / ____________ Age: ________
4 Client: __________________________________________________
5 Start: _______________ End: _______________
6 Fee: ________ Payment method: Check / Cash / Invoiced / Escrow / ____________
7 Present: Client / Owner / Tenant / Realtor / Builder / Contractor / ____________
8 Occupied: Yes / No / No, but furnishings present / ____________
9 Weather: Clear / Partly cloudy / Cloudy / Rain / Snow / Fog / ____________
10 Temp: Cold / Cool / Warm / Hot / ____________ Ground: Wet / Damp / Dry / Frozen / ____________
11 Front of structure faces: N / S / E / W / ____________ Entrance faces: N / S / E / W / ____________
12 Foundation: Unfinished basement / Finished basement / Crawlspace / Slab / Post-pier / ____________
13 Excluded: Septic / Security / Irrigation / Pool / Hot tub / Well / Shed / Playground / Sauna / Outdoor lighting / Vacuum / Water filter / Water softener / Sound / Intercom / Generator / Sport court / Sea wall / Outbuildings / ____________
14 Excluded: Furniture, stored items: Many | Some Winterized
15 Utilities not on: Natural gas | Propane | Water | Electricity | Oil
16 General warnings: Gas leak No CO alarms Pre-1979 Abandoned oil tank
Exterior
1 Footing material: Concrete / Masonry / Logs / None / Not visible / ____________
2 Foundation material: Concrete / Concrete block / Post-pier / Brick / Stone / Steel on block (mfg homes) / ____________
3 Wall structure: Wood frame / Steel frame / Concrete block / Pan Abode / Log / Brick / Stone / Straw bale / ____________
4 Wall cover: Wood clapboard / Wood panels / Comp wood clapboard / Comp wood panels / Cement-based clapboard / Cement-based panels / Wood shingles / Wood shakes / Vertical wood / Brick veneer / Stone veneer / Stucco / EIFS / Metal / CAB / Vinyl / Masonite / ____________
5 Driveway: Asphalt / Concrete / Aggregate / Gravel / Dirt / Permeable concrete / Porous pavers / Cobblestone / None / N/A / ____________
6 Sidewalk: Concrete / Aggregate / Paving stones / Gravel / Wood / Brick / None / N/A / ____________
7 Exterior door material: SC Wood / SC Steel / SC Fiberglass / Sliding glass / Wood panel / Glass panel / HC Wood / ____________
8 Excluded: Vegetation, stored items: Foundation and/or walls | Retaining walls
9 Foundation: Cracks: Minor | Moderate | Major Large tree near Footing above grade
10 Retaining walls: Missing or inadequate guardrails above
11 Cracks or deterioration: Monitor, maintain | Repair-replace | Repair-replace w/ engineer
12 Rotten timbers: Monitor | Repair-replace | Repair-replace w/ engineer
13 Driveway: Minor cracks | Repair-replace | Trip hazard Reseal asphalt New gravel
14 Drain: Missing | Inadequate | Clogged
15 Sidewalks and patios: Minor cracks | Repair-replace | Trip hazard
16 Undermined: Minor | Major, replace slabs
17 Fences and gates: Repair-replace | Repair-replace (major) Repair gates
18 Soil contact: Soil w/in 6" of siding/trim | Soil w/in 6" of siding/trim, rot Unlined wood planter boxes
19 Rotten landscaping timbers: Replace | Replace steps
20 Vegetation: <1' from exterior Stump near exterior Large tree, fall hazard
21 Firewood contact Trees against roof | Trees against roof with damage
22 Drainage: Soggy yard or standing water Negative perimeter slope: Soil | Pavement
23 Downspouts: Loose or detached Missing Extensions missing or ineffective
24 Dented, crushed, damaged Terminate above roof surface
25 Gutters: Missing Damaged Leaking Poor slope End caps missing Rusted 26 Crawlspace vents: Blocked
27 Screens: Missing Deteriorated Clogged Wells: Missing Inadequate
28 Siding: Gaps at penetrations Deteriorated Incomplete or missing
29 Composition wood fiber: Minor, maintain | Moderate, maintain/replace | Major, replace
30 Brick veneer: Minor cracks | Moderate cracks/deterioration | Major cracks/deterioration
31 Cement-asbestos: Asbestos warning Deteriorated
32 Stucco: Repair-replace EIFS Repair-replace stucco
33 Logs: Uncaulked up-facing cracks Rot Sealant failed Masonry contact Bark
34 Soffits: Deteriorated Rot Water stains: Dry | Wet
35 Soffit vents: Screens missing or deteriorated Screens painted or blocked
36 Cantilever: No soffit cover | No insulation or soffit cover Unvented soffit
37 Fascia: Deteriorated Rot Rafter ends rotten
38 Deck: Reseal deck | Reseal deck & rail Repaint deck | Repaint deck & rail Narrow spacing
39 Substructure: Excluded Needs bracing Ledger board: No lag screws No flashing
40 Soil at support posts | Soil at support posts with rot Inadequate clearance to soil below
41 Stairs: Wobbly Rot: Base of stringers | Treads
42 Non-uniform risers: Warning | Repair Non-standard: Warning | Repair
43 Hand rails: Missing Ungraspable Loose Not continuous or too short
44 Guardrails: Wide gaps Missing Wobbly Low Climbable
45 Electrical: Cover plates: Missing | Broken
46 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire
47 Broken Scorched Hot-neutral reverse Loose No power Worn
48 Damaged waterproof cover | Not waterproof | Need in-use cover
49 GFCI receptacles: Won't trip | Won't trip with tester Won't reset Energized when tripped 50 Non-GFCI outside within 6'-6" of ground Damaged by paint Bad GFCI, can't verify others
51 Light fixtures: Inoperable No bulb(s) Loose or substandard Deteriorated
52 Not rated for use in wet location No caulk around back plate
53 Wiring: Exposed Not terminated Splices not in box Extension cord Lamp cord 54 Wires run overhead to trees
55 Exposed wiring at disconnect switch: Install lock | Repair (emergency disconnect)
56 Paint & caulk: Caulk missing or deteriorated Paint or stain failing: Entire | Some areas
57 Window glazing putty missing or deteriorated Caulked head flashing
58 Hose bibbs: No anti-siphon No water No handle Need screws Leaks Winterized
59 Supply pipes outside subject to freezing
60 Vents: Vent caps: Deteriorated Missing
61 Plumbing vents: <3' above opening | <10' from opening
62 Direct vent: Inadequate clearance to openings or ignition sources Installed upside down 63 Propane tank: <3' from opening | <3' from electric meter | <10' from ignition source
64 250/500 gal. tank <10' | 1000 gal. tank <25' | Underground 1000 gal. tank <10'
65 Hornet, bee or wasp nest
Roof
1 Roof inspection method: Traversed / From eaves / From ground / From windows / Not inspected / ____________
2 Roof type: Gable / Cross-gable / Hipped / Cross-hipped / Pyramidal / Shed / Flat / Mansard / Gambrel / A-frame / ____________
3 Roof covering: Composition / Wood shakes / Torch down / Built up / Metal / Concrete tile / Clay tile / Slate / EPDM / Rolled / ____________
4 Estimated age of roof: ____________________
5 Gutter & downspout material: Aluminum / Steel / Plastic / Copper / Galvanized / Wood / Built-in / None / ____________
6 Roof ventilation: Adequate / Inadequate / None visible / Unable to determine / ____________ 7 Excluded: Couldn't traverse
8 Snow obscures: Partially | Completely Debris obscures: Partially | Completely
9 Vegitation and maintenance: Clean gutters Clean roof Moss Trees overhanging 10 Trees against roof | Trees against roof with damage
11 Age: Beyond service life < 5 yrs left
12 New composition roof will need: Tear-off | Sheathing | Both
13 Flashing: Deteriorated, rusted Lead improper at top of vent pipes
14 At chimney: Deteriorated, substandard No counterflashing
15 Rubber boots: Deteriorated Lifting or improperly installed
16 Roof design: Slope-slope | Slope-wall | Slope-flat No cricket above wide chimney
17 Siding in contact with shingles below
18 Composition: Deteriorated or missing Popped nails Raised shingles Pressure washed
19 < 3/12 slope Pabco HO25
20 Shakes: Deteriorated | Clean and preserve | Both
21 Metal: Dented or damaged Failing paint Rust Asphalt or tar sealant
22 Concrete or tile: Chipped or cracked Slipped Missing
23 Flat roof: Coating failed Ponding Gaps: Seams | Penetrations | Both
24 Parapet walls: Deteriorated, substandard flashing | Slopes towards exterior
25 Masonite Woodruf: Warning | Repair-replace
26 Vents: Improper B-vent termination
27 Plumbing vent: <6" above surface | <12" from vert. surface Blocked: Caps | Debris
Garage
1 Excluded: Stored items: Perimeter | Perimeter and center | Vehicle door(s) | All
2 Appliances with no protective barrier Walls or ceiling not fire-rated
3 Garage-house door: Not fire-rated | Pet door No auto-close | Repair/replace auto-close
4 Weatherstrip: Missing | Deteriorated | Both Gaps around when closed
5 Vehicle door: Replace | Repair/replace Water stains - caulk, paint Lock inoperable or difficult
6 Not balanced Broken spring No restraining cable on springs Difficult to open or close 7 Weatherstrip: Missing | Deteriorated | Both
8 Vehicle door opener: Inoperable Mechanical auto-reverse inoperable or needs adjustment 9 Lock not disabled Infrared photo eyes: Too high | Inoperable | None
10 Control button: Too low or within reach of children | Loose
11 Entry door: Deteriorated entry Weatherstrip missing or deteriorated Hollow core
12 Attic access: Hatch missing | Hatch not fire-rated Pull-down stairs not fire-rated
13 Stairs: Wobbly Garage-house step missing
14 Non-uniform risers: Warning | Repair Non-standard: Warning | Repair
15 Handrails: Missing Ungraspable Loose Not continuous or too short
16 Guardrails: Wide gaps Missing Wobbly Low Climbable
17 Electrical: Cover plates: Missing | Broken
18 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire
19 Broken Scorched Hot-neutral reverse Loose No power Worn
20 GFCI receptacles: Won't trip | Won't trip with tester Won't reset Energized when tripped 21 Non-GFCI in garage (excluding 1 for freezer) Damaged by paint Bad GFCI, can't verify others
22 Wiring: Exposed Not terminated Splices not in box Loose Extension cord Lamp cord
23 Rodent evidence: Light to moderate | Heavy
Attic
1 Inspection method: Viewed from hatch / Traversed / Partially traversed / Not inspected / ____________
2 Roof structure: Trusses / Rafters / Not visible / ____________
3 Ceiling structure: Trusses / Ceiling beams / Not visible / ____________
4 Insulation material: Fiberglass loose / Fiberglass roll/batt / Mineral wool loose / Mineral wool roll/batt / Cellulose loose / Cellulose roll/batt / Vermiculite / None / ____________
5 Insulation depth: _______________ Estimated R value: ____________________
6 Excluded: No attic | No access hatch | Hatch inaccessible | Some areas inaccessible
7 <1" clearance to flue Water stains on wood: Dry | Wet
8 Ceiling insulation: Vermiculite, asbestos warning Paper facing on batts exposed
9 Substandard | Uneven | Missing in some areas | None | None at skylight
10 In contect with recessed lighting: Not IC rated | No visible rating
11 Exhaust fans: No duct | Duct broken or collapsed | No vent cap
12 Access hatch: No insulation over | No weatherstrip Uninsulated pull-down stairs
13 Electrical: Cover plates: Missing | Broken
14 Wiring: Not terminated Splices not in box Loose Extension cord Lamp cord
15 Attic fan: Inoperable | Noisy, vibration
16 Vents: Blocked | Screens deteriorated or missing Inadequate ventilation
17 Water pipe insulation: None | Repair
18 Rodent evidence: Light to moderate | Heavy
19 Hornet, bee or wasp nest
Electric service
1 Service type: Underground / Overhead / ____________
2 Protection: Breakers / Fuses / ____________
3 Amperage: 60 / 100 / 125 / 150 / 200 / 400 / ____________ Upgrade to 200 amp service
4 Voltage: 120 / 120/240 / 3 phase, 4 wire, 120/208 / ____________
5 Location of main service switch: ________________________________________
6 Location of sub panels: ________________________________________
7 Location of main disconnect: Top / Bottom / Top bank / All / ____________
8 Service entrance conductor material: Aluminum / Copper / Copper-clad aluminum / ____________
9 System ground: Ground rod / Cold water / Concrete encased electrode / Copper / Rebar / ____________
10 Main disconnect rating: 60 / 100 / 125 / 150 / 200 / N/A / ____________
11 Branch circuit wiring type: NM sheathed / BX / Knob and tube / Copper / Aluminum multi-strand / Aluminum solid-strand / ____________
12 Aluminum wiring present: No / Yes / Can't verify / ____________
13 Smoke detectors: Yes / No / ____________
14 Excluded: Interior low voltage lighting
15 Panel cover not removed: Stored items, debris Paint/wallpaper Arcing noises
16 Shelving, cabinets or structure Equipment energized Water: On floor | Leaking into panel
17 Service drop wires: Frayed In trees
18 < 10' above ground | < 12' above driveway | < 3' from openings
19 <3' above 3/12 roof or steeper | <8' above a flat roof | <18" above roof ridge
20 Service entrance wires: Frayed Loose point of attachment
21 Drip loop: None Substandard
22 Service mast: Loose Bent Broken or damaged
23 Meter: Missing or broken seal Tap before meter
24 Federal Pacific Zinsco panel | Zinsco breakers
25 Service panel (substitute "sub panel" as needed): Inadequate working space
26 Missing or inadequate legend Tap before main >6 switches or hand movements
27 Bushing missing Undersized wire Wires not terminated Contamination
28 Double or multi tap Doubled or bundled neutrals Open knockout
29 Burned or melted wires or insulation No anti-oxidant Old fuses: Eval | Replace
30 Burned or damaged circuit breaker
31 GFCI breaker: Won't trip Won't reset
32 AFCI breaker: Won't trip Won't reset Recalled (blue test button)
33 Service panel cover: None or not installed Not flush Open closure
34 Screws: Missing Pointed or too-long In contact with conductors
35 Grounding and bonding: Plastic pipe Dielectric connectors
36 Clamp on rod: Missing | Loose | Rusted or corroded
37 Clamp on pipe: Missing | Loose | Rusted or corroded
38 Sub panel: Neutrals and grounds bonded at sub-panel
39 Branch circuit wiring: Aluminum solid strand Knob and tube: Energized | Abandoned
40 Incompatible components: Undersized: Meter base | Service conductor | Main service panel
Water heater
1 Estimated age: ____________________ Type: Tank / Instantaneous / ____________
2 Energy source: Electricity / Natural gas / Propane / Oil / ____________
3 Capacity: 30 / 40 / 47 / 50 / 52 / 65 / 66 / 80 / Not visible / ____________
4 Manufacturer: American / American Proline / American Standard / A.O. Smith / AquaStar / Bosch / Bradford White / Envi-Ro-Temp / General Electric / Hotpoint / Reliance / Rheem / Richmond / Row Con / Rudd / State / Takagi / U.S. Craftmaster / Vanguard / Whirlpool / ____________
5 Model: ________________________________________
6 Water temperature: ____________________
7 Excluded: Shut off
8 Obscured by: Insulated jacket | Stored items | Permanent enclosure
9 Temp > 120 Flame or source of spark <18" from garage floor Reverse plumbed
10 Undersized No catch pan or drain Circulation pump installed
11 Age: Near 8-12 years | 8-12 years or older | Unknown, may be old
12 Corrosion: On tank | Water stains below | Both On fittings
13 Earthquake straps: Missing | Substandard
14 Supply valve: Missing | Handle missing
15 T-P valve: Missing | Leaking
16 Drain line: Missing Routed up >6" from floor <6" from floor Undersized In crawlspace >4 elbows
17 Electric: Substandard wiring No insulated pad
18 Gas: Inadequate combustion air Melted insulation by draft hood
19 No drip leg Scorch marks Scale on burner, pilot assemblies or at draft hood
20 Flame: Yellow | Noisy (whistling) | Floats | Too high
21 Flame sheild missing or loose: Inner | Outer | Both
Heating and cooling
1 Estimated age: ____________________
2 Primary heat energy source: Natural gas / Electric / Oil / Wood / Propane / Solar / Coal / ____________
3 Primary heat type: Forced air / Heat pump / Baseboard / Fan wall units / Radiant / Hot water / Gravity / Circulating pump / Steam / Up draft / Down draft / Horz draft / Standard / Medium / High / Gas fireplace/stove / ____________
4 Primary A/C energy source: Electric / Natural Gas / Propane / N/A / ____________
5 Primary A/C type: Split system / Heat pump / N/A / ____________
6 Distribution: Sheet metal / Flex / Metal pipe / Plastic pipe / Not visible / N/A / ____________
7 Manufacturer: Amana / American Standard / Armstrong / Bryant / Carrier / Coleman / General Electric / Goodman / Heil / Intertherm / Janitrol / Lennox / Luxaire / Payne / Rheem / Ruud / Tempstar / Thermopride / Trane / York / ____________
8 Model: ________________________________________
9 Filter location: Return air above / Return air below / Behind grill / Base of furnace / Top of furnace / ____________
10 Last service date: ____________________
11 Excluded: <60 degrees, can't eval A/C Can't verify heat source in every room
12 No response: Furnace | Boiler | Heat pump | A/C
13 Shut off: Furnace | Boiler | Heat pump | A/C condensing unit
14 Age: Furnace: Near 15-20 years | 15-20 years or older | Unknown, may be old
15 Heat pump condensing unit: Near 15-20 years | 15-20 years or older | Unknown, may be old 16 A/C condensing unit: Near 8-15 years | Older than 8-15 years | Unknown, may be old
17 Service: Now & annually (heat pump or AC) Now & annually (gas or oil) Now & annually (hydronic)
18 Now & every few years Perform heat exchanger CO test
19 Return air: Open in basement - gas & oil Gaps in attached garage No gaps below interior doors
20 Fresh air: Fresh air timer not set Keep air supply ports open 24-7
21 Filters: Replace now | Wash now | Maintain in future
22 Deteriorated | Not secure | Wrong size | None
23 Ducts: Broken or disconnected Broken hangers Lying on ground
24 Flex duct: Sagging | Supports > 5' apart | Narrow support straps | All
25 Asbestos on ducts: Warning | Deteriorated
26 Ducts need cleaning: Debris, dirt, dust | Rodents | Mold | New construction
27 Insulation: None | Deteriorated
28 Combustion air, clearances and disconnect: Inadequate combustion/dilution air
29 Flame or spark <18" above floor in garage <1" from B-vent flue <2" from double wall flue
30 Single wall flue: <18" w/o draft hood <9" w/ draft hood and oil <6" w/ draft hood and gas
31 Cabinet: <6" from top or sides of furnace/boiler <24" from front of oil furnace/boiler
32 <18" from front of gas/electric furnace or boiler
33 Gas: Rusted or cracked heat exchanger No drip leg
34 Gas supply lines: Rust Flexible connector: Through cabinet | Subject to damage
35 Flame: Yellow/orange | Floating | Noisy or dancing | Pop | Rollout | Changes with fan on
36 Oil: Flame not orange to yellow-white, or sooty Oil smell or soot
37 Oil tank: Buy replacement insurance Leaking | Rust
38 Buy contamination & clean up insurance (for tanks still in use in WA state only)
39 Oil supply lines: Leaking Subject to damage No shut-off valve No filter
40 Barometric draft damper: Defective Spilling exhaust gases
41 Air handler: Noise or vibration Loose v-belt No catch pan in attic - heat pump or A/C 42 Evaporator coils: Ice Cooling fins: Deteriorated | Dirty | Both
43 Outside condensing unit: Not level Noise or vibration No disconnect
44 Refrigerant line insulation deteriorated or missing Cooling fins: Deteriorated | Dirty | Both 45 Inadequate clearance: Vegetation | Structure
46 A/C supply air: Not cool enough | Too cool
47 Hydronic: Open system, Legionnaire's disease
Plumbing and laundry
1 Water pressure: ____________________
2 Location of main water shut-off: ________________________________________
3 Location of main water meter: ________________________________________
4 Location of main fuel shut-off: ________________________________________
5 Visible fuel storage systems: ________________________________________
6 Type: Public / Private / Community well / ____________
7 Service pipe: Copper / Galvanized / PE / Lead / Not visible / ____________
8 Supply pipe: Copper / Galvanized / CPVC / PE / Polybutylene / Not visible / ____________
9 Vent pipe: Plastic / Galvanized / Cast iron / Copper / Not visible / ____________
10 Drain pipe: Plastic / Galvanized / Cast iron / Copper / Not visible / ____________
11 Waste pipe: Plastic / Galvanized / Cast iron / Copper / Not visible / ____________
12 Excluded: Laundry appliances Washer had clothes in it
13 Main shut-off not found Meter not found Inspect, pump septic
14 Pre-1986 lead solder warning Lead service pipe Polybutylene
15 Public supply pressure: > 80 psi | < 40 psi, warn | < 40 psi, repair Need expansion tank 16 Galvanized steel supply: Old, advise, monitor | Corrosion, leaks or low flow
17 Copper supply: Pin holes or corrosion Steel hangers
18 Drain and waste: Active leak Stains: Monitor | Repair
19 Oakum packing deteriorated or missing Hanger straps: Broken | Substandard
20 Waste cleanout: Cap missing Bad seal Shows wear: Public sewer | Private septic
21 Laundry: No catch pan or drain for washer | No visible drain Fan timer not set
22 Laundry sink: Unanchored Concrete cracked | Concrete cracked and leaking
23 Dryer duct: Plastic or foil Kinked Broken or disconnected None
24 Needs cleaning Too long Routed vertically Sheet metal screws
25 Water softener discharge: To septic system To sump pump Near foundation
26 Air gap: None or substandard Inaccessible
27 Sump pump: Installed Inoperable Couldn't test No GFCI Not on dedicated circuit
28 No check valve No pit liner
Fireplaces, woodstoves and chimneys
1 Fireplace type: Masonry / Masonry with metal liner / Metal prefab / ____________
2 Woodstove type: Metal / Metal insert / Ceramic / ____________
3 Chimney type: Masonry / Metal / ____________
4 Excluded: Fireplace firebox obscured by ashes or debris
5 Gas: No gas | No response | No controls found
6 Hearth: <18" deep | Deteriorated
7 Clean flue: Annually for all Now: Fireplace | Woodstove
8 Fireplace: Rusted liner Gaps between firebox and face
9 Fireplace firebrick: Minor cracks | Repair, replace
10 Refractory panels: Repair | Replace
11 Damper: Stuck open or closed Deteriorated Missing
12 Woodstove: In garage Replace firebrick Eval and verify safe installation
13 Inadequate clearances: Flue pipe | Stove | Heat shield
14 Chimney: Missing: Screen | Rainproof cover | Both
15 Too short Pie plate Wood burning flue shared with oil or gas flue
16 Repoint mortar Crown deteriorated Cracked flue tiles Major masonry repairs
17 Unlined wood burning | Unlined with gas appliance | Unlined with oil furnace
18 Gas: Vent-free warning Glass: Fogged | Soot
19 Conversion: Damper can close No glass doors
Basement
1 Insulation material: Fiberglass roll/batt / None / ____________
2 Pier/support post material: Wood / Bearing wall / Concrete / Masonry / Steel / ____________
3 Beam material: Solid wood / Built up wood / Laminated wood / Steel / ____________
4 Floor structure above: Wood joists / Engineered wood joists / Wood trusses / 2x6 T&G / Not visible / ____________
5 Structural: Post-beam missing ties Overspanned: Joists | Beams
6 Notches and bored holes: Joists, various substandard | Studs, various substandard
7 Joist notches: In middle 1/3 | >1/6 of depth | >1/4 of depth at end
8 Joist bored holes: <2" from edge | >1/3 of depth
9 Stud notches: >40% of depth | >25% of depth, bearing wall
10 Stud bored holes: Bored hole <5/8" from edge | >60% of depth | >40% of depth, bearing wall
11 Water: Standing water or wet areas | Past water intrusion
12 Entry door: Deteriorated entry Repair/replace lockset
13 Weatherstrip: Weatherstrip missing or deteriorated | Replace
14 Stairs: Wobbly
15 Non-uniform risers: Warning | Repair Non-standard: Warning | Repair
16 Hand rails: Missing Ungraspable Loose Not continuous or too short
17 Guardrails: Wide gaps Missing Wobbly Low Climbable
18 Electrical: Cover plates: Missing | Broken
19 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire
20 Broken Scorched Hot-neutral reverse Loose No power Worn
21 GFCI receptacles: Won't trip | Won't trip with tester Won't reset Energized when tripped
22 Damaged by paint
23 Wiring: Exposed Not terminated Splices not in box Loose Extension cord Lamp cord
24 Rodent evidence: Light to moderate | Heavy
Kitchen
1 Appliances older than 10 or 15 years
2 Dishwasher: Inoperable No water No high loop or air gap | No air gap
3 Loose or missing bracket Water beneath Noisy Kick plate missing, loose or deteriorated
4 Bad door seal Door handle loose or missing Leaking at air gap
5 Refrigerator: Inoperable Ice maker turned off No ice or water
6 Bad door seal Broken or missing shelving Door handle(s) loose or missing Uses GFCI
7 Range hood: None Light: Light inoperable | Missing bulb(s)
8 Fan: Inoperable Noisy Vents indoors Filter(s) missing Undersized exhaust duct
9 Microwave: Inoperable Turntable inoperable No turntable Digital display defective 10 Range/Oven/Stove top: Inoperable: Bake | Broil | Burner(s) | Oven light
11 No anti-tip bracket Knob(s) missing or damaged Door handle(s) loose or missing
12 Bake element standoffs missing or damaged Downdraft exhaust: Inoperable | Noisy
13 Food disposal: Inoperable Noisy Substandard wiring Corroded or at end of life
14 Hot water dispenser: Inoperable Disconnected
15 Electrical: Cover plates: Missing | Broken
16 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire
17 Broken Scorched Hot-neutral reverse Loose No power Worn
18 GFCI receptacles: Won't trip | Won't trip with tester Won't reset Energized when tripped 19 Non-GFCI within 6' of sink Damaged by paint Bad GFCI, can't verify others
20 Light fixtures: Inoperable No bulb(s) Loose or substandard Deteriorated
21 Closet lighting: Open lamp Incandescent <12" clearance | Fluorescent <6" clearance
22 Exhaust fans: Inoperable or inadequate Noisy
23 Plumbing: Shut-off valve handle missing Supply line leak
24 Faucets: Loose or missing handle Leaks when off Leaks when on Reverse plumbed
25 Sinks: Sprayer inoperable or defective Enamel deteriorated
26 Sink drains: Leak Clogged or drains slowly Substandard repair Flexible pipe
27 No trap S-trap
28 Cabinets: Deteriorated Loose Missing shelving or components
29 Hardware loose and/or missing Drawers difficult to operate No pulls or handles
30 Water damage below sink: Minor | Needs repair
31 Countertops: Minor deterioration Deteriorated Loose laminate
32 Needs caulk at backsplash Cracked or broken concrete
33 Tile, stone and grout: Deteriorated Reseal grout
34 Floors: Refinish wood floor Gaps between tiles in wet areas
35 Vinyl: Deteriorated | Deteriorated in wet areas
36 Tile, stone and grout: Deteriorated | Deteriorated in wet areas Reseal grout
Bathrooms
1 Electrical: Switch within reach of shower Cover plates: Missing | Broken
2 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire
3 Broken Scorched Hot-neutral reverse Loose No power Worn
4 GFCI receptacles: Won't trip | Won't trip with tester Won't reset Energized when tripped
5 Non-GFCI within 6' of sink Damaged by paint Bad GFCI, can't verify others
6 Light fixtures: Inoperable No bulb(s) Loose or substandard Deteriorated
7 Closet lighting: Open lamp Incandescent <12" clearance | Fluorescent <6" clearance
8 Exhaust fans: None with shower Inoperable or inadequate Noisy
9 Plumbing: Shut-off valve handle missing Supply line leak
10 Faucets: Loose or missing handle Leaks when off Leaks when on Reverse plumbed
11 Sinks: Enamel deteriorated Cracked or broken Loose Stopper missing or defective 12 Sink drains: Leak Clogged or drains slowly Substandard repair Flexible pipe
13 No trap S-trap
14 Toilets: No water Loose | Loose w/ wet or damaged floor Clogged or weak flush
15 Runs Flapper valve did not reseat Cracked or broken: Bowl | Tank | Tank lid | All
16 Bathtubs: Enamel deteriorated Clogged or drains slowly Tile or grout deteriorated
17 Caulk missing or deteriorated: At floor | At surround | At base of spout | All
18 Jetted tub GFCI: None visible | No access, cannot verify
19 Showers: Clogged or drains slowly Tile or grout deteriorated Diverter valve defective 20 Caulk missing or deteriorated: At floor | Around surround | All
21 Cabinets: Deteriorated Loose Missing shelving or components
22 Hardware loose and/or missing Drawers difficult to operate No pulls or handles
23 Water damage below sink: Minor | Needs repair
24 Countertops: Minor deterioration Deteriorated Loose laminate
25 Needs caulk at backsplash Cracked or broken concrete
26 Tile, stone and grout: Deteriorated Reseal grout
27 Floors: Refinish wood floor Gaps between tiles in wet areas
28 Vinyl: Deteriorated | Deteriorated in wet areas
29 Tile, stone and grout: Deteriorated | Deteriorated in wet areas Reseal grout
Interior rooms
1 Heating and cooling: No visible source of heat
2 Recalled Cadet heaters, FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW, ZC
3 Registers: Missing Loose or not flush Damaged Weak flow or no flow
4 Baseboard heaters: Baseboard heater deteriorated Electric receptacles above
5 Electrical: Doorbell: Inoperable Button loose or damaged
6 Smoke alarms: None >10 years old Replace batteries Too few | Damaged or missing | Both
7 Cover plates: Missing | Broken
8 Receptacles: Open ground, rewire or replace with 2-prong | Open ground, rewire
9 Broken Scorched Hot-neutral reverse Loose No power Worn Childproof caps
10 Few receptacles | 2-pronged receptacles | Few & 2-pronged receptacles
11 GFCI receptacles: Won't trip | Won't trip with tester Won't reset Energized when tripped 12 Non-GFCI within 6' of sink Damaged by paint Bad GFCI, can't verify others
13 Light fixtures: Inoperable No bulb(s) Loose or substandard Deteriorated
14 Old fixtures Need 3-way switches at both ends: Hall | Stairs
15 Closet lighting: Open lamp Incandescent <12" clearance | Fluorescent <6" clearance
16 Wiring: Exposed Not terminated Splices not in box Extension cord Lamp cord 17 Fans: Whole-house fan: Inoperable Noisy
18 Ceiling fans: Inoperable Wobbly, unbalanced <7' from floor
19 Ceiling: Minor cracks Dry stains, monitor Wet stains: Roof leak | Plumbing leak
20 Pre-1979 asbestos popcorn: Intact, warn | Deteriorated, needs repair or abatement
21 Walls: Minor cracks
22 Windows: Won't open Lock missing or inoperable Springs broken Vents closed 23 Glass: Broken Double pane seal(s) failed Non-tempered w/in 18" of floor
24 Screens: Missing Holes or tears
25 Bedroom egress: Too high | Won't open, or opening too small | Both
26 Doors: Deteriorated interior Won't latch Binds in jamb No gap for return air
27 Keyed lock or deadbolt on interior door
28 Locksets: Missing Loose Damaged Installed backwards
29 Entry door: Deteriorated entry Weatherstrip missing or deteriorated Hollow core
30 Deadbolt: Key-only, no handle Inoperable or difficult
31 Sliding glass doors: Deteriorated Difficult to open/close Lock inoperable or difficult
32 Double pane seal(s) failed Handle missing or loose
33 Sliding screen doors: None for only source of ventilation Deteriorated
34 Holes or tears Difficult to open/close
35 Stairs: Door swings out over stairs
36 Non-uniform risers: Warning | Repair Non-standard: Warning | Repair
37 Handrails: Missing Ungraspable Loose Not continuous or too short
38 Guardrails: Wide gaps Missing Wobbly Low Climbable
39 Floors: Not level Refinish wood floor Squeaky
40 Vinyl: Deteriorated | Deteriorated in wet areas
41 Gaps between tiles in wet areas
42 Carpet: Loose | Loose with trip hazard Needs cleaning Deteriorated
43 Tile, stone and grout: Deteriorated | Deteriorated in wet areas Reseal grout
44 Miscellaneous:
45 Trim: Missing | Damaged | Both
46 Fixtures: Missing | Damaged | Both
47 Rodent evidence: Light to moderate | Heavy
48 Lead paint: Intact | Poor condition
Pretty decent little form, there. (Disclaimer - I am a home inspector)
I think the questions for many investors lie where their ability to conduct a good visual review surpasses their comfort level with some systems or portions of the home. Flipping, investing, and rehabbing do not nessesarily require any specialist background or knowledge (and lots of people do not want to be on the roof).
I get many calls from investors to do "INVESTOR" inspections - this is a specialty inspection style I offer which provides a professional evaluation of all the major systems and components of the property at a lower rate. The idea is that you may already be comfortable with much of what you see, and have plans for the cosmetics, but you may not be so sure of the electric panel or foundation walls, for example.
I have no doubt that there are many investors who are skilled contractors and capable of performing a pretty fair inspection - but if you have any areas where you are not as certain, or if you just want another professional evaluation - get a professional inspection.