This great blog by James Quarello illustrates one of the "Duh!" moments of sustainable building and living - think about very simple every day physics (in this case, heat rises) and you can make a big difference. 

Via James Quarello - ASHI Certified CT Home Inspector (JRV Home Inspection Services, LLC):

A while back I wrote a blog on the occurrence of air stratification in homes. This is when warm and cold air layer in a room. Recently I came across a classic example of this during an energy audit. The infrared image at the right very distinctly shows how the air has layered in this room. The temperature difference between the ceiling and the floor, over 15 º F.

The second infrared image shows the same occurrence in a connected room.

The reasons for this happening are for one physics and the other poor installation of the heating ducts.

In Connecticut we heat our homes most of the year. Consequently the heating registers should be located when at all possible in or near the floor.

In the two rooms pictured the heating registers were placed in or near the ceiling. The bright spot in the second image is the heating register.

With the idea to evenly heat the room the installers placed return air ducts near the floor thinking the warm air will be drawn down by the ducts. Not surprisingly that theory did not pan out. What's more if return ducts could be installed near the floor, they just as easily could have been made heating ducts. This was true in the second room as well. A storage room behind the wall affords ample space to install the registers down low.

This is a standard case of physics winning out over mechanics, but by applying a little more mechanics the problem can be resolved. In the room with the high ceiling putting in a ceiling fan will almost assuredly resolve the issue. Ceiling fans are a good energy efficient way to "homogenize" the room air. Running the fan will evenly warm the space causing the heating system to run less often.

The second half of the solution would be to relocate the registers. Doing this will be more costly and labor intense than putting in the fan, but will further achieve the desired benefit of a more evenly heated space.

Identifying a problem such as this one would be difficult without the aid of an infrared camera. However an HVAC installer should be cognizant of this effect when placing duct work. In the instances when ducts are unable to be ideally placed suggesting a ceiling fan be installed would be good advice.

Layer cake is tasty, but not on a wall.

James Quarello
JRV Home Inspection Services, LLC

To find out more about our other high tech services click on the links below:

Learn more about our Infrared Thermal Imaging & Diagnostics services. Learn more about our energy audits, the Home Energy Tune uP®.

 

2 Comments on Layer Cake

FEB
14
387,575 Points 15 Featured Posts Outside Blog

Tricia:  I have never seen anything quite like this.  Wow.  So much to learn... and it appears this infrared thermal imaging tells quite a bit.  Thanks so much for sharing.

12:55am • #1
FEB
15
244,284 Points 1 Featured Post

I too have never seen anything like this. Great post with good info.

10:42am • #2

This blog does not allow anonymous comments

 
Trishhighres Rainmaker_large

Tricia Jumonville, EcoBroker®, ASP®

Georgetown, TX

More about me…

ERA Colonial Real Estate

Office Phone: (512) 868-0403

Cell Phone: (512) 423-6466

Email Me

A blog about things Texas, about things horsie, about real estate issues, about life in the country, about food, about whatever strikes my fancy pertaining to life, the universe, and everything and, especially, real estate. <!-- Start of StatCounter Code -->
hitcounter
<!-- End of StatCounter Code -->


Links

Archives

RSS 2.0 Feed for this blog

Find TX real estate agents and Georgetown real estate on ActiveRain.