Disclaimer: ActiveRain Corp. does not necessarily endorse the real estate agents, loan officers and brokers listed on this site. These real estate profiles, blogs and blog entries are provided here as a courtesy to our visitors to help them make an informed decision when buying or selling a house. ActiveRain Corp. takes no responsibility for the content in these profiles, that are written by the members of this community.
© 2013 ActiveRain Corp. All Rights Reserved
4 Comments on Photos Of Attic Bypasses, The Least Understood Attic Problem
Reuben - wonderful pictures and captions. Looks like the sheetrock cutout that fell into the open chase in the last photo has combustible paper that is now in direct contact with a gas vent.
House would be a good candidate for an energy audit. Penetrations through top plates for wires and cables should have been "fire-stopped"
Thanks Hank - good catch with the drywall!
Reuben:
Nice pictures!
There is one note you left out; when passing thru an insulated assembly, a shield is required around the B vent.
This is what I say in my reports:
As per the mechanical code (G2426.4), a shield "shall be installed to provide clearance between the vent and the insulation material..." I strongly recommend installing such a shield for safety.
PS- I hope the code police don't come and arrest me for inserting a code section in my reports!
Darren - thanks!
Hey, I think you can quote as much code as you want to. Just because you're not required to quote code doesn't mean you shouldn't. I've never heard a good reason for not quoting code, but I've heard a lot of home inspectors give ridiculous reasons why not to quote code. I'm sure you have too.
I sometimes put that comment about the insulation lacking a 1" clearance to the vent in my reports, but not always. When I do, I include this diagram. What is your reason for strongly recommending this?