Admin

UL Listed Carbon Monoxide Alarms are Useless for Low Levels of CO

By
Home Inspector with Structure Tech Home Inspections

This has happened to me dozens of times, so I have to assume it happens to other home inspectors around the country every day.  I report a problem with a gas appliance, saying there is exhaust gas leaking in to the house, and I say it needs to be fixed because it's a safety hazard; exhaust gas contains carbon monoxide.

The next day I get an accusatory call from the seller or their agent, asking why the brand new CO alarm never went off if there was a safety hazard at the house.  What's being insinuated in these cases is 'you're wrong'.  In a recent phone call like this, the seller even went so far as to ask me why he was still alive.

I didn't engage.

The simple answer is that UL listed carbon monoxide alarms will not alert you to low levels of carbon monoxide.  Carbon monoxide alarms keep people from dying; they don't eliminate all health risks.  Underwriters Laboratory standard UL2034 requires carbon monoxide alarms to not sound off when exposed to carbon monoxide levels under 30 parts per million (ppm).  This means that if you have a furnace with a CO reading of 25 ppm in the flue gas, you could place the carbon monoxide alarm right inside the furnace's vent and it would never go off.

Even at higher CO levels, UL listed CO alarms might take a long time to sound off - long enough for you to start experiencing symptoms of carbon monoxide poisoning.  Seattle home inspector Charles Buell just wrote a post on this topic, where he tells the story of how a kitchen stove was producing CO levels at over 600 parts per million, but the UL listed CO alarm never made a peep.

Does this mean that low levels of carbon monoxide are safe?  No.  There are numerous studies saying that low levels of carbon monoxide exposure cause health problems; there are links to many such studies at CO-Experts Home Page.  Even though this web site looks like it was designed in the early 90's without being touched since, it has some good information.

How do you know if your equipment is leaking exhaust gas?  The best way to know is to have it professionally checked.  A combustion analyzer can easily locate exhaust gas leaks.  Most of the exhaust gas leaks that I find seem to happen at the same locations over and over.

Gas Fireplaces often leak exhaust gas around the glass if the glass has been removed for cleaning, but not secured back in place properly.

Exhaust gas leak at fireplace

Furnaces often leak exhaust gas at the burner area, or at the draft hood.  A telltale sign of an exhaust gas leak on a furnace is a rust line curving up around the burner shield or draft hood.

Exhaust gas leak at furnace

Hole in draft hood

Boilers often leak exhaust gas right through the jacket - pay special attention to any rust holes in the jacket of the boiler.

Exhaust gas leak at boiler

Water heaters leak exhaust gas right at the draft hood (backdrafting), or leak exhaust gas at the burner area when the heat roll-out shield is missing.

This is only a partial list of the places that you could have exhaust gas leaks in your home, but this easily makes up 95% of the exhaust gas leaks that I find during home inspections.  If you suspect an exhaust gas leak in your home at any of these locations, hire a professional to check it out.

For the best protection against low levels of carbon monoxide, buy a low-level carbon monoxide detector.  This should be considered a supplement to the UL listed CO alarm that is required - see Minnesota requirements for CO Alarms.

Show All Comments Sort:
Gita Bantwal
RE/MAX Centre Realtors - Warwick, PA
REALTOR,ABR,CRS,SRES,GRI - Bucks County & Philadel

Thank you for the information. I will share it with others. They should make better CO detectors.

Jan 08, 2013 07:54 PM
Jay Markanich
Jay Markanich Real Estate Inspections, LLC - Bristow, VA
Home Inspector - servicing all Northern Virginia

Just like Charlie's article Reubs, good stuff.  It doesn't go off because there is not enough time or exposure.  But the danger still exists.

Jan 08, 2013 08:28 PM
Clint Mckie
Desert Sun Home, commercial Inspections - Carlsbad, NM
Desert Sun Home, Comm. Inspection 1-575-706-5586

Hi Reuben,

Many time I have the buyers and sellers asking 'why'. This is a good example on how the state of the art detectors are not good enough for the simplest of tasks. Like low levels of C/O.

Many times the seller thinks you are out to get the home for a lesser price. I don't are what the home sells for and I'm sure you don't either.

Safety is first and foremost.

Have a good day in Minnesota.

Best, Clint McKie

Jan 08, 2013 08:42 PM
Leesa Finley
RED Properties - Wake Forest, NC
RED Properties - Raleigh NC Real Estate

This is great information, Reuben!  I actually had this situation come up recently and I was the listing agent.  We were not accusatory and understood what the Buyer's inspector was saying.  LOW levels can be very dangerous and are just not detected.  Fortunately, we all came to a peaceful resolution - shame on those that "jump" on you!

Jan 08, 2013 09:58 PM
Charles Buell
Charles Buell Inspections Inc. - Seattle, WA
Seattle Home Inspector

Reuben, hopefully this will help get the word out.

Jan 09, 2013 04:03 AM
Christine McDaniel
Christine McDaniel Realty, LLC - Avon, IN
Broker Associate

Reuben - This is a very timely post for me.  My son just bought a home.  The fireplace clip is missing so we are looking into that.  I'll now be checking the other appliances.

Jan 09, 2013 08:34 AM
James Quarello
JRV Home Inspection Services, LLC - Wallingford, CT
Connecticut Home Inspector

Good info on what is quite likely an unknown potential hazard. 

Jan 09, 2013 09:36 PM
Reuben Saltzman
Structure Tech Home Inspections - Minneapolis, MN
Delivering the Unbiased Truth.

Gita - thanks!

Jay - exactly.  Many people have the mistaken idea that if the CO alarm doesn't sound off, everything is perfect.

Clint - boy, you sure are right about that.  My interest is in presenting accurate information.

Leesa - good for you, and thanks.

Charles - ditto.

Christine - keep that fireplace off until it's fixed.

James - thank you sir... and CONGRATULATIONS on your award!  http://www.ashireporter.org/HomeInspection/Articles/Chapter-News/2469

Jan 09, 2013 10:14 PM
Donald Hester
NCW Home Inspections, LLC - Wenatchee, WA
NCW Home Inspections, LLC

Reuben, Great post. CO has a 5 hour half life so you can be building up CO (forming carboxyhemoglobin.) This then inhibits the ability for he hemoglobin to transport oxygen. Just not a good thing.

Jan 10, 2013 10:40 PM
Robert Butler
Aspect Inspection - Montreal West Island, QC
Montreal Home Inspector | Aspect Inspection

Great article. Important issue for clients to be advised of. Another potential source for CO would be attached or connecting garages.

Jan 12, 2013 03:14 AM