Special offer

If You Have These Smoke Alarms, Get Rid Of Them!

Reblogger Chuck Carstensen
Real Estate Agent with RE/MAX Results MN#20344949 WI#93113-94

I thought this was worth a reblog, because its better safe then sorry when dealing with smoke alarm and the potential devastation of one does not work when needed. 

See information below that are am sharing!

Original content by Steve Stenros

If You Have These Smoke Alarms, Get Rid Of Them!


There are two types of smoke alarms, photoelectric and ionization. Which one should you use? Ionization alarms respond marginally faster to an open or “fast-flame” fire than a photoelectric smoke alarm. On average, ionization alarms will react about 30 to 90 seconds faster to this type of fire. 


However, nearly 100% of residential fire fatalities are from smoke inhalation and not from the actual fire. Most fatal fires happen at night while the occupants are asleep. An ionization alarm will respond 30 to 90 minutes slower to a smoldering fire than a photoelectric alarm. In these situations, a photoelectric alarm will alert the occupants and allow a safe exit about 96% of the time. Ionization alarms will give sufficient warning less than 40% of the time, meaning that 60% of the time someone may die!


A slow response time isn't the only problem with an ionization alarm. Nuisance tripping can occur when cooking, showering, etc. Many times, people become frustrated and intentionally disable the detectors, leaving their household completely unprotected. Approximately two-thirds of all residential fire deaths occur in homes that are unprotected. Ionization alarms account for over 85% of disabled alarms. Most of the remaining fire deaths occur when a smoke alarm sounds too late for the occupants to escape.




Significant research going back to the mid-1970's clearly shows ionization alarms are slow to react to smoldering fires. I
t has taken decades, but there is finally a growing public awareness of this problem. The International Association of Firefighters (IAFF) recently took a stand, and now recommends that only photoelectric smoke alarms be installed. 


Which Ones Do You Have?


If your alarm has a “Hush” feature, it is probably an ionization unit. If the label mentions radioactive material, Americium-241, or if there is an "I" in
the model number- it is probably an ionization alarm. If there is any doubt, play it safe and replace the units with photoelectric alarms.








What About Combination Smoke/CO Alarms?


Combination photoelectric/carbon monoxide (CO) alarms are available. Smoke alarms should be replaced every 10 years. CO detectors should be replaced every 5 to 7 years. With a combination unit, you are either replacing the smoke alarm too soon, or relying on a CO detector that is past its expiration date. Separate units make more sense. Photoelectric alarms provide the best protection in real-world fires. This year, don't just replace your smoke alarm batteries – replace your alarms with photoelectric units and recommend that your families, friends, and neighbors all do the same!


Steve Stenros- First Choice Inspections, a CREIA MCI and ICC certified inspector provides home inspections in San Diego, Orange, and Riverside counties in southern California. Clients receive a FREE lifetime appliance RecallChek with every standard inspection. Steve can be reached for appointment at 888-335-3040. If You Have These Smoke Alarms, Get Rid Of Them!

 

 


             Steve Stenros, MCI         Biz card photo

             Master CREIA Inspector

             Certified Infrared Thermographer

             FHA/HUD Inspector- #V975

                                       203k Consultant

                                     888-335-3040

 

My Recent Home Inspector Blogs:

My Home Inspector Said Aluminum Wiring Will Catch My House On Fire!

Does Your Weep Screed Weep?- Temecula Home Inspector

Deck Repair Gone Awry!- Del Mar Home Inspection

A Home Inspector's ActiveRain Success Story

Dealing With Dirty Laundry At A Home Inspection

How To Kill A Home Inspector

Roof Issues At A Temecula Home Inspection

Carlsbad Home Inspector Runs Into Bee Invasion!

Have You Tried Efflorescence?- La Jolla Home Inspection

Crawlspaces: A Defect-Rich Environment!- San Diego Home Inspector- Part 2

Crawlspaces: A Defect-Rich Environment!- San Diego Home Inspector- Part 1

 

 

Posted by

 

 

 

 

 

 

Chuck Carstensen is a Realtor with RE/MAX Results in Elk River and Cambridge, MN.  Helping buyers, sellers and investors in great Minnesota counties like Sherburne, Isanti, Wright, Anoka, Chisago, Hennipen and Mille Lacs. He is a Certified Distressed Property Expert (CDPE).

Contact Chuck by emailing him at chuck.carstensen@results.net or by phone at 612-290-3809. 

 

Jon Quist
REALTY EXECUTIVES ARIZONA TERRITORY - Tucson, AZ
Tucson's BUYERS ONLY Realtor since 1996

OK, my house has four of these alarms. What that means is that hundreds of homes in my neighborhood also have them.

Incredible tip. Thank you so much.

Off to the store to get new ones!

Aug 03, 2011 05:28 PM